Press and hold the Menu button for at least 5 seconds. The display will show item #1 in the table below. Press Menu to ad-
vance to the next menu item. Press
or to change a menu item options.
1F97-0671CONFIGURATION
INSTALLER/CONFIGURATION MENU
CONFIGURATION MENU
Menu
Ref.
Press
Button
Displayed
Factory (Default)
Press or to
select from listed options COMMENTS
1 MENU (GAS) ELE GAS setting: furnace controls the blower
ELE setting: thermostat controls the blower
2 MENU (3) CS 0, 1, 2, 4, 5, 6 Selects Cool Savings
Value 1 (low) to 6 (high),
Value 0 disables feature
3 MENU (On) E OFF Selects Energy Management Recovery (EMR) On or OFF.
4 MENU (ME) CR Heat SL, FA Adjustable Anticipation:
Selects heating cycle rate for MS or SS in #1 only
5 MENU (ME) CR Cool SL, FA Adjustable Anticipation:
Selects the cycle rate for cooling
6 MENU (OFF) CL CL On Compressor Lockout Time
7 MENU Cool Off, Heat Auto Heat Auto Cool Off,
Heat Off with Fan icon,
Heat Off without Fan icon
Cool Off, Auto Off
System Mode Configuration
with Automatic Changeover capability
8 MENU (On) dL dL OFF Selects Display Light On or OFF
9 MENU 0
(current temperature)
1 HI, 2 HI, 3HI, 4 HI,
1 LO, 2 LO, 3 LO, 4 LO
Adjustable Ambient Temperature Display
10 MENU °F °C Selects Fahrenheit/Celsius Temperature Display
11 MENU (On) b OFF May select Beeper OFF to stop audible key feedback
12 MENU (7) P 3, 0 Defaults 7-day programming (P7) but non-
programmable (0) or 5/1/1 programming (P3)
is available on most models.
13 MENU (4) PS 2 Selects Program periods per day:
4 = Morn, Day, Eve, Night
2 = Day, Night
14 MENU (On) Heat AS OFF Automatic Schedule for heat mode
15 MENU (On) Cool AS OFF Automatic Schedule for cool mode
16 MENU Remote (OFF) On Selects Remote Sensor On/OFF
MENU Remote
(In)
Outdoor Selects Remote Sensor to outdoor
NA is Remote Sensor OFF
MENU Indoor (On) Loc OFF Selects Local Sensor (in thermostat) to OFF. N/A if Remote is
selected to Outdoor
17 MENU (On) dS Off Selects Automatic Daylight Saving Time option
18 MENU (OFF)
Keypad Lockout
L, P, Limit Selects one of 3 Keypad Lockout configurations
L - Total Keypad Lockout
P - Partial Keypad Lockout
(Up and Keys still work)
Limit - Limited Temperature RANGE
MENU (000)
Keypad Lockout
1-999 Selects personal lockout code. 000 is NOT A VALID CODE.
19 MENU (99) HL Heat L 62 to L 98 Selects Limited HEAT Range Temperature
20 MENU (45) Ll Cool L 46 to L 82 Selects Limited COOL Range Temperature
21 MENU (OFF) Change Filter On Selects Filter Change-Out Indicator On or OFF
MENU Change Filter (200 h) 25-1975 h Change Filter time in 25 hour increments. This menu only ap-
pears if On is selected in above.
22 MENU (OFF)
Change UV Lamp
On Selects UV Lamp
Timer: On/OFF
MENU (350)
Change UV Lamp
25-1975 Selects number of Days between changing UV Lamp.
23 MENU (o) On Cool Heat On (b) Selects operation of the reversing valve terminal (O/B) output as an
O or B terminal
24 MENU Returns to Normal Operation