1F95-1277CONFIGURATION
To enter the menu: Press the Menu touch key. Press and hold for 5 seconds the Installer Config touch key. This displays
menu item #1 in the table below. Press
to advance to the next menu item or to return to a previous menu item. Press
or
to change a menu item option.
CONFIGURATION MENU
Menu
Reference
Number
Program-
mable
Non-
Program-
mable
Press
key
Displayed
Factory
(Default)
Press
or
to select from
listed options COMMENTS
111
MS 2 HP 1, HP 2, SS 1
Selects Multi-Stage (MS2, No Heat Pump), Heat Pump 1
(HP1, 1 compressor), Heat Pump 2 (HP2, 2 compressor
or 2 speed compressor), or Single Stage.
222
(ELE) GAS
GAS setting: furnace controls blower.
ELE setting: thermostat controls blower.
333
(7) Days, P
5-1-1 or 0
Programs per week. (0 = non-programmable)
44NA
(4) PS
2 Programs periods per day.
4 = Morning, Day, Evening, Night
2 = Day, Night
554
Cool-Off-
Heat-Auto
Cool-Off-Heat,
Heat Off, Cool
System switch configuration in non heat pump mode.
Cool-Off-Heat-
Emer-Auto
Cool-Off-Heat-Emer,
Off-Heat-Emer, Cool-Off
System switch configuration, heat pump mode.
66NA
(On) E
OFF Selects Energy Management Recovery, E (with programming option on)
775
(FA) Heat, Cr SL
Selects Adjustable Anticipation, cycle rate, Heat
886
(FA) Cool, Cr SL
Selects Adjustable Anticipation, cycle rate, Cool
997
(FA) Em, Cr/AU SL
Selects Adjustable Anticipation, cycle rate auxiliary, (This item is
only to appear if HP1 or HP2 is selected above).
10 10 8
(OFF) CL On
Selects Compressor Lockout.
11 11 9
(On) dL OFF
Selects Continuous Display backlight and intensity.
12 12 10
(LO) dL HI
Selects Backlight Intensity.
13 13 11
0
(temperature)
4, LO to 4, HI
Selects Adjustable Ambient Temperature Display [range -4 (LO) to
+4 (HI)].
14 14 12
°F °C Selects °F/°C Display (temperature units in Fahrenheit or Celsius).
15 15 13
(On) b OFF
Selects audible Beeper On/Off.
16 16 14
(On) dS OFF
Selects Daylight Saving Time calculation.
17 17 15
(On) Heat, AS OFF
Selects Automatic Schedule for comfort temperature Programming,
heat mode.
18 18 16
(On) Cool, AS OFF
Selects Automatic Schedule for comfort temperature Programming,
cool mode.
19 19 17
(OFF) CS,
Cool Savings
1-2-3-4-5-6
Selects Cool Saving Feature and amount.
20 20 18
(99) Heat, HL 62-98
TEMPERATURE LIMIT, HEAT (max. heat set point).
21 21 19
(45) Cool, LL 46-82
TEMPERATURE LIMIT, COOL (min. cool set point).
22 22 20
OFF,
Keypad Lockout
L (total), P (partial),
Temperature Limit
(limited temperature range)
Selects Keypad Lockout.
000 001-999
Selects Keypad Lockout Combination (active only if keypad Lockout
is selected).
23 23 21
(On) Heat, FS OFF
Fast second stage of heat (not available if SS1 is selected above).
24 24 22
(On) Cool, FS OFF
Fast second stage of cool (not available if SS1 or HP1 is selected
above).
25 25 23
Remote (OFF) On
Remote temperature sensor, enable/disable.
Remote, In Outdoor Remote
Remote temperature sensor (Indoor/Outdoor).
(On) LS OFF
Local temp. Sensor enable/disable (only when Indoor Remote is
selected On).
26 26 24
(05) dF 5-50 Selects Dual Fuel Feature and set point (in Fahrenheit) (applicable
only when HP1 or HP2 is selected).
(60) Cd 0-99 Selects Compressor delay in seconds (only when dF is selected >5).
27 27 25
(OFF) Change
Filter
On Selects Change filter feature.
200 Hours 25-1975 (in increments of
25 hours)
Change filter, duration hours.