INSTALLER/CONFIGURATION MENU
To enter the menu: Press the Menu touch key. Press and hold for 5 seconds the Installer Cong touch key. This displays
menu item #1 in the table below. Press
to advance to the next menu item or to return to a previous menu item. Press
or
to change a menu item.
Installer Note: To default the programming, clock and Conguration Menu to the Factory Default Settings, press the
,
and SYSTEM keys simultaneously. The thermostat display will go blank for a few seconds, and then all segments will display
momentarily.
CONFIGURATION MENU
Menu
Reference
Number
Program-
mable
Non-
Program-
mable
Press
Button
Displayed
(Factory
Default)
Press
or to
select from listed
options Comments
1 1 1 (ELE) GAS GAS setting: furnace controls blower
ELE setting: thermostat controls blower
2 2 2
Days, (7) P 5-1-1 or 0 Programs per week. (0 = non-programmable)
3 3 NA
PS (4) 2 Program periods per day
4 = Morning, Day, Evening, Night
2 = Day, Night
4 4 3
Cool-Off-
Heat-Auto
Cool-Off-Heat,
Off-Heat, Cool-Off
System switch conguration
5 5 NA
E (On) OFF Selects Energy Management Recovery, E (with programming
option on)
6 6 4
Cr, Heat (FA) SL Selects Adjustable Anticipation, cycle rate, Heat
7 7 5
Cr, Cool (FA) SL Selects Adjustable Anticipation, cycle rate, Cool
8 8 6
CL (OFF) On Selects Compressor Lockout
9 9 7
dL (On) OFF Selects Continuous Display backlight & intensity
10 10 8
dL (LO) HI Selects Backlight Intensity
11 11 9
0 4, LO to 4, HI Selects Adjustable Ambient Temperature Display [range -4 (LO)
to +4 (HI)]
12 12 10
°F °C Selects °F/°C Display (temperature units in Fahrenheit or Celsius)
13 13 11
b (On) OFF Selects audible Beeper On/Off
14 14 12
dS (On) OFF Selects Daylight Saving Time calculation
15 15 13
AS, Heat (On) OFF Selects Automatic Schedule for comfort temperature
Programming, heat mode
16 16 14
AS, Cool (On) OFF Selects Automatic Schedule for comfort temperature
Programming, cool mode
17 17 15
CS, (OFF)
Cool Savings
1-2-3-4-5-6 Selects Cool Saving Feature & amount
18 18 16
HL, Heat (99) 62-98 TEMPERATURE LIMIT, HEAT (max. heat set point)
19 19 17
LL, Cool (45) 46-82 TEMPERATURE LIMIT, COOL (min. cool set point)
20 20 18
OFF,
Keypad Lockout
L (total), P (partial),
Temperature Limit
(limited temperature range)
Selects Keypad Lockout
000 001-999 Selects Keypad Lockout Combination (active only if keypad
Lockout is selected)
21 21 19
Remote (OFF) On Remote temperature sensor, enable/disable
In, Remote Outdoor Remote Remote temperature sensor (Indoor/Outdoor)
LS (On) OFF Local temp. Sensor enable/disable (only when Indoor Remote is
selected On)
22 22 20
Change Filter
(OFF)
On Selects Change lter feature
200 Hours 25-1975 (in increments
of 25 hours)
Change lter, duration hours