3
Single
Stage
(SS)
Energized
in Cool
Mode
Energized
in Heat,
Off Mode
System
O
RH
+
B
CLASS II
TRANSFORMER
HOT
24VAC
NEUTRAL
120VAC
W
G
C*
-
Energized
on call
for Cool
(Com-
pressor)
Blower/
Circula-
tor Fan
Energiz-
ed on
call for
Heat or
Cool
(if ELE
is sel-
ected)
24 Volt
(Hot)
Cool
DC
supply
voltage
to re-
mote
Temp-
erature
Sensor
Remote
Temp-
erature
Sensor
signal
DC
Return
to
Remote
Temp-
erature
Sensor
Energized
on call for
Heat
Third wire
for 3-wire
zone valve
Y
RC
S
6
L
{
To Remote Temperature Sensor
24 Volt
(Hot)
Heat
24 Volt
Com-
mon
(option-
al)
CLASS II
TRANSFORMER
120VAC
HOT
24VAC
NEUTRAL
COOLING
Diagnostic
Indicator
(See
Note
)
1
Jumper
Remove Jumper Wire
between RH & RC
Single
Stage
(SS)
Energiz-
ed in
Cool
Mode
Energized
in Heat
or Off
Mode
System
O
RH
+
B
CLASS II
TRANSFORMER
HOT
24VAC
NEUTRAL
120VAC
W
G
C*
-
Jumper
Energized
on call
for Cool
(Com-
pressor)
Blower/
Circula-
tor Fan
Energiz-
ed on
call for
Cool &
for Heat
(if ELE
is sel-
ected)
24 Volt
(Hot)
Cool
DC
supply
voltage
to re-
mote
Temp-
erature
Sensor
Remote
Temp-
erature
Sensor
signal
DC
Return
to
Remote
Temp-
erature
Sensor
Energized
on call for
Heat
Third
wire for
3-wire
zone
valve
Diagnostic
Indicator
(See
Note
)
Y
RC
S
6
L
{
To Remote Temperature Sensor
24 Volt
(Hot)
Heat
24 Volt
Com-
mon
(option-
al)
1
Single Stage Connections
Refer to equipment manufacturers' instructions for specic system
wiring information.
This thermostat is designed to operate a single-transformer or two-
transformer system.
You can congure the thermostat for use with the following systems:
SINGLE STAGE gas, oil or electric.
After wiring, see INSTALLER CONFIGURATION section for proper
thermostat conguration.
Single Stage System with Single Transformer
Single Stage with Two Transformers
* Common connection
required for fault or
malfunction indication
and remote sensor.
NOTE: If continuous backlight or hardwired
power input are desired but do not function
in both HEAT and COOL modes, cut the
heating transformer 24V wires and tape off.
Connect the neutral circuit disconnected
from the heating transformer to the neutral
circuit of the cooling transformer. Discon-
nect the wire to the RH terminal and install
a jumper between RH and RC. Depending
on the system requirements, replace the
cooling transformer with a 75VA class II
transformer if needed.
WIRING CONNECTIONS
* Common connection
required for fault or
malfunction indication
and remote sensor.
NOTE ➀: Connection for Call for Service diagnostic indicator compatible with mechanical or electronic condenser control with Comfort Alert