S
E2
–
To + or S1
To S or S2
To - or S3
Thermostat SubbaseThermostat Subbase
Thermostat SubbaseThermostat Subbase
Thermostat Subbase
+
S
E2
–
To +
To OT
To -
Outdoor Probe
Remote SensorRemote Sensor
Remote SensorRemote Sensor
Remote Sensor
NoteNote
NoteNote
Note: When using shielded cable, connect shield of 18 or
20 gauge 3 connector cable to - or S3 on thermostat
subbase.
Remote Outoor SensorRemote Outoor Sensor
Remote Outoor SensorRemote Outoor Sensor
Remote Outoor Sensor
Staging Multi-Stage or Heat Pump Touchscreen Thermostat (1F95-1277) Indoor/Outdoor Remote
Sensor Wiring (F145-1328/F145-1378)
If connecting
outdoor service
Troubleshooting ChartTroubleshooting Chart
Troubleshooting ChartTroubleshooting Chart
Troubleshooting Chart
To function correctly and read temperature accurately, the thermostat must have constant 24-volt power. If the thermostat
temperature is steadily dropping, reading low, or reads
08°08°
08°08°
08° when a remote sensor is installed, it can be traced to one of the
three following conditions.
ConditionCondition
ConditionCondition
Condition
TestTest
TestTest
Test
CommentsComments
CommentsComments
Comments
1. Loss of 24-volt power. On models with batteries, remove the batteries and re-install For the sensor to read correctly,
thermostat. If the display is blank, check heating and coolingthe 24-volt system power
mustmust
mustmust
must
system to determine why 24-volt power is absent.be present. Some systems may
require an isolation relay to pro-
vide constant power to the
thermostat. Limit or safety
devices in the equipment can
also cause a power interruption.
2. A broken wire on S1, Disconnect sensor wires at thermostat. Attach a short pieceRepair or replace the 3 wire
S2 and S3 or (+, SA, -) (2') of three-wire shielded cable to S1, S2 and S3 or (+, SA, shielded cable. Be sure the
from the thermostat to -) on the subbase. Bring the remote sensor to the thermostatremote wire run is not parallel
the remote. location and attach S1, S2 and S3 or (+, S, -) respectively.to line voltage wires that carry
Reattach thermostat. If the temperature begins to climb heavy inductive loads, or across
(slowly), it is reading correctly. If it reads correctly with the 2' fluorescent light ballasts that
length but improperly when attached to the wire run, it may cause an inductance to be
.tatsomreht eht ot dettimsnart.nur eriw eht ni tluaf a setacidni
3. A shorted or Because it is an electronic sensor, there are no Ohm valuesR
eplace remote sensor
.
damaged remote sensor. to test. If correct conditions as listed in 1 & 2 above and the
temperature stays at or near
08°08°
08°08°
08°, it indicates a shorted or
damaged remote sensor.
NoteNote
NoteNote
Note: Digital thermostats and remote sensors acclimate very slowly to temperature change. It may take an hour or more for
the temperature to acclimate to the room temperature from a low temperature reading as outlined above. To expedite the
room temperature display use the reset instructions listed in the installation instructions for the thermostat model you are
working with. When reset, the thermostat will default to a room temperature of 70° and begin sensing room temperature. Be
sure to reconfigure the installer menu for a remote sensor because the reset function may cancel remote sensing.
Single Stage Thermostat Remote Sensor Wiring (F145-1328)
Thermostat SubbaseThermostat Subbase
Thermostat SubbaseThermostat Subbase
Thermostat Subbase
+
S
E2
–
To + or S1
To S or S2
To - or S3
Remote SensorRemote Sensor
Remote SensorRemote Sensor
Remote Sensor
NoteNote
NoteNote
Note: When using shielded cable, connect shield of 18 or
20 gauge 3 connector cable to - or S3 on thermostat
subbase.
S1 S2 S3
S1 S2 S3
or
+S -
Troubleshooting ChartTroubleshooting Chart
Troubleshooting ChartTroubleshooting Chart
Troubleshooting Chart
To function correctly and read temperature accurately, the thermostat must have constant 24-volt power. If the thermostat
temperature is steadily dropping, reading low, or reads
08°08°
08°08°
08° when a remote sensor is installed, it can be traced to one of the
three following conditions.
ConditionCondition
ConditionCondition
Condition
TestTest
TestTest
Test
CommentsComments
CommentsComments
Comments
1. Loss of 24-volt power. On models with batteries, remove the batteries and re-install For the sensor to read correctly,
thermostat. If the display is blank, check heating and coolingthe 24-volt system power
mustmust
mustmust
must
system to determine why 24-volt power is absent.be present. Some systems may
require an isolation relay to pro-
vide constant power to the
thermostat. Limit or safety
devices in the equipment can
also cause a power interruption.
2. A broken wire on S1, Disconnect sensor wires at thermostat. Attach a short pieceRepair or replace the 3 wire
S2 and S3 or (+, SA, -) (2') of three-wire shielded cable to S1, S2 and S3 or (+, SA, shielded cable. Be sure the
from the thermostat to -) on the subbase. Bring the remote sensor to the thermostatremote wire run is not parallel
the remote. location and attach S1, S2 and S3 or (+, S, -) respectively.to line voltage wires that carry
Reattach thermostat. If the temperature begins to climb heavy inductive loads, or across
(slowly), it is reading correctly. If it reads correctly with the 2' fluorescent light ballasts that
length but improperly when attached to the wire run, it may cause an inductance to be
.tatsomreht eht ot dettimsnart.nur eriw eht ni tluaf a setacidni
3. A shorted or Because it is an electronic sensor,
there are no Ohm valuesReplace remote sensor
.
damaged remote sensor. to test. If correct conditions as listed in 1 & 2 above and the
temperature stays at or near
08°08°
08°08°
08°, it indicates a shorted or
damaged remote sensor.
NoteNote
NoteNote
Note: Digital thermostats and remote sensors acclimate very slowly to temperature change. It may take an hour or more for
the temperature to acclimate to the room temperature from a low temperature reading as outlined above. To expedite the