White Rodgers 36C04U-438 Manual de Instalação

Consulte online ou descarregue Manual de Instalação para Fogões White Rodgers 36C04U-438. White Rodgers 36C04U-438 Installation Instructions Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 6
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
Printed in U.S.A.
PART NO. 37-5837B
Replaces 37-5837A
9947
WHITE-RODGERS
WHITE-RODGERS DIVISION
EMERSON ELECTRIC CO.
9797 REAVIS ROAD
ST. LOUIS, MISSOURI 63123-5398
Operator: Save these instructions for future use!
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE
INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY
AND/OR PROPERTY DAMAGE.
DESCRIPTION
This multi-function gas control combines, into a single
compact package, the functions of a 3-position manual
valve, a main gas valve, pressure regulator and 100%
shut-off automatic pilot. The pilot gas outlet accepts a
1
4
pilot line connection.
Pilot Gas Outlet:
Located at outlet end of the valve
Type of Gas:
Suitable for all domestic heating gases
Pressure Rating:
1
2
lb. per sq. in.
Pressure Regulator Adjust Range (typical;see con-
trol label):
Natural Gas: 2.5 to 5.0” W.C.
LP Gas: 7.5 to 12” W.C.
Ambient Temperature: -40° to 175°F
Thermocouple (24 Volt and 120 Volt types):
Use W-R Type H06
Pilot Generator (750 mV types):
Use W-R Type G01A-32
Mounting: Any position except upside down
SPECIFICATIONS
INLET BOSS
UP OR DOWN
UPRIGHT
LEFT OR RIGHT
Upright, 90° from upright or vertical
Figure 1. Mounting positions
NOTE: Control shown may not be identical to replacement control.
ON
OFF
INSTALLATION INSTRUCTIONS
Type 36C04, 36C14
Step-Opening
Combination Gas Control
(24 Volt, 120 Volt & 750 mV Models)
OFF
PILOT
ON
OFF
PILOT
ON
Model No. Voltage
36C04
36C04A
36C04U
36C14
36C14A
36C14U
Type of Gas
Nat
Nat
Nat
LP
LP
LP
24 Volt
120 Volt
750 mV
24 Volt
120 Volt
750 mV
PIPE SIZES/CAPACITIES
Pipe Size
(inches)
Capacity (BTU/hr) at
1” pressure drop across valve
1
2
” x
3
8
1
2
” x
1
2
1
2
” x
3
4
3
4
” x
3
4
100,000
230,000
230,000
280,000
162,000
372,600
372,600
453,600
Nat. Gas
(1000 BTU/cu. ft.,
64 Sp. Gr.)
LP Gas
(2500 BTU/cu. ft.,
1.53 Sp. Gr.)
Vista de página 0
1 2 3 4 5 6

Resumo do Conteúdo

Página 1 - Type 36C04, 36C14

Printed in U.S.A.PART NO. 37-5837BReplaces 37-5837A9947WHITE-RODGERSWHITE-RODGERS DIVISIONEMERSON ELECTRIC CO.9797 REAVIS ROADST. LOUIS, MISSOURI 6312

Página 2 - THE FOLLOWING PRECAUTIONS

2MAIN PIPING CONNECTIONSAll piping must comply with local codes, ordinances,and/or national fuel gas codes.1. Turn off electrical power to the system

Página 3 - PILOT GAS CONNECTION

3INSTALLATION (cont’d)SYSTEM WIRINGREFER TO AND FOLLOW THE APPLIANCEMANUFACTURER’S WIRING DIAGRAM. REFER TOFIGS. 4 & 5 FOR TERMINAL IDENTIFICATION

Página 4 - Figure 8. Gas valve top

4THERMOCOUPLE CONNECTION(For 24 VAC and 120 VAC Models)The thermocouple connection should be clean to ensuregood electrical contact. Run the thermocou

Página 5 - LIGHTING INSTRUCTIONS

5LIGHTING INSTRUCTIONSFOR YOUR SAFETY READ BEFORE LIGHTINGWARNING!If you do not follow these instructions exactly, a fire or explosion may result caus

Página 6 - 9797 Reavis Road

If you need more information about this product, please write to us at:WHITE-RODGERS DIVISION, Emerson Electric Co.9797 Reavis RoadSt. Louis, MO 63123

Comentários a estes Manuais