8day you wish to change and followSteps 10, 11 & 12. You can also copythe program from one day to another.To copy, press HOLD/COPY. Thedisplay wil
985°F (29°C)85°F (29°C)85°F (29°C)85°F (29°C)85°F (29°C)85°F (29°C)85°F (29°C)5:00 PM5:00 PM5:00 PM5:00 PM5:00 PM5:00 PM5:00 PM78°F (25°C)78°F (25°C)7
10MONTUEWEDTHUFRISATSUN13 4 5 6 3 4 5 62Personal Program Schedule1 Occupied (OCCU)2 Unoccupied (UNOC)3 Start Time4 Heating Temperature5 Cooling T
11the room temperature (65°F) and thesetpoint (70°F) is 5°. 5° X 8 minutesper °F = 40 minutes. The setpoint onthe display will actually change todispl
12Fahrenheit or Celsius Tempera-ture Display.(User menu, Item 3) This thermostatis factory set to display temperature inFahrenheit. If you prefer, you
13keypad to prevent unauthorizedtampering with the program. Twolevels of security are available, TotalKeypad Lockout or Partial KeypadLockout. Total K
14compressor failure by “locking out”the compressor. This ensures that thecompressor will stay off for at leastfive minutes on each cycle. When thethe
15contact the manufacturer of yourheating/cooling equipment.System and Thermostat Diag-nostics.The display will indicate CHECKSYS if the room temperat
16as well as the HOLD period expirationtime. Press the TIME FWD or TIMEBACK keys until you reach the timeyou would like it to resume theprogram. The T
17Featuresa poor location for sensing temperatureor if you want to install the thermostatin a separate room to prevent tamper-ing. After installing an
18LO). AVG is the default setting. Asetting of HI gives a sensor moreimportance and a setting of LO givesless importance.Daylight Savings Time Button.
19Thermostat Startup After TotalPower Loss.On installation, or when power isrestored after a total power loss to thethermostat, your thermostat willau
20Activate RUN PRG by Telephone 13Adjustable Temperature Display -- 11Air Filter Change-out Indicator---- 14Arm Chair Programming ----------- 18Automa
INTRODUCTIONThank you for purchasingyour new Comfort-Set® 90Series thermostat. Your newWhite-Rodgers Thermostatuses solid state micro-computer technol
2ORIENTATIONTHE THERMOSTAT BUTTONSSee inside front cover for illustrationshowing button locations.1 (Blue arrow) Lowers temperaturesetting (45°F or 7°
3FAN AUTOHRSCHECK BATTERY STAT SYSTEM°FAMMONPRGFAN ONHEATHEATHRSCHECK BATTERY°FAMMON WED THU FRI SAT SUNTUEWED THU FRI SAT SUNTUE18 1819202121
4The configuration menus allow you toset certain thermostat operatingcharacteristics to your system orpersonal requirements.To enter the User Configur
51Step Press Button(s) Displayed Press or to select: COMMENTS Ref (Factory Default) Page0 °F(room temperature)5 LO to5 HI
69 FONE (Icon)(OFF)ON10 COMP RUN TIME(00)(Compressor run timein hours)12Returns to normal operation.11 AUX RUN TIME(00)(AUXILIARY run timein hours)Tel
7PROGRAMMINGMANUAL OPERATIONYour Comfort-Set® 90 Series thermo-stat can be used to control temperaturemanually (without programming). Formanual operat
Comentários a estes Manuais